
- #Filmora 9 import from filmora 8 update
- #Filmora 9 import from filmora 8 driver
- #Filmora 9 import from filmora 8 full
- #Filmora 9 import from filmora 8 Bluetooth
Station / Offset, Ground to Grid scale factor – Fixed issue that the scale factor was not being applied. #Filmora 9 import from filmora 8 full
Automap – Fixed window goes full screen no matter the windows settings issue. #Filmora 9 import from filmora 8 Bluetooth
ComNav – Fixed Bluetooth connect issue with Windows 10.FOIF FieldGenius – Fixed issue so the Observation Toolbar shows red.
#Filmora 9 import from filmora 8 driver
Leica – Remove Leica 1100 driver no longer supported device.ĭ EFECTS F IXED in MicroSurvey FieldGenius Software 10.4.1.1.None Microsurvey FieldGenius 10.4.1.1 Software released on June 24, 2020 eSurvey E100 – Updated driver to address GSM issue.Changing GNSS Tolerance – Fixed wait dialog does not close issue.Observation Toolbar – Fixed bug when switching to staking mode.CHC i80 – Updated driver to support new firmware version.KOLIDA K1PRO and K20s – Added New Drivers.Stonex – Add S990A and S980 – Added New Driver.Tersus – Add support for GSA and GSV messages.Leica Devices – Add support for Satel 900MHz Radio.
Tersus GNSS Devices – Updated reference distance for GNSS. Hemisphere S631 GNSS – Added New Driver. This is a service pack release for FieldGenius to add support for new survey instruments and fix high priority defects. None Microsurvey FieldGenius 10.4.1.2 Software released on August 21, 2020 Multiset Structured – Angle only backsight is not available. LandXML – LandXML alignments containing a sequence of Spiral-Curve-Spiral-Curve-Spiral are not properly displayed. Photo Notes – Camera rotation is not supported. #Filmora 9 import from filmora 8 update
Local Transformation – Resolved issue when having a RTS transformation applied along with a local transformation no longer reverts the RTS transformation parametersĬHC i90 – IMU tilt compensation issues when position update rate not set to 1Hzĭisto S910 – First photo taken with project can provide an error, additional photos are taken and stored fine. MDOT Cutsheet Report Export – Fixed issue where the offset values were recorded incorrectly. Tersus Oscar – Resolved issue when setting up reference station to use the correct. DWG/DXF Import – Resolved issue with coordinates being rounded when importing circle. LandXML Surface Import – Fixed issue where TIN surface models are not preserved on. Hungary-Vitel2014 – Updates to the system to address an issue with computing positions in certain areas.ĭ EFECTS F IXED in MicroSurvey FieldGenius Software 10.4.1.2. Romania70 – Updates to the coordinate dictionaries to address a translation. Japan Coordinate Systems – Updates to the Japan coordinate systems to reflect updated shifts in the region. Barbados National Grid System – Added support for Barbados National Grid System. SLD 99 System – Update to the SLD 99 Sri Lankan system to resolve computation. Tersus Oscar – Add support for CMR or RTD Correction Format When Configuring Reference Station. GeoMax Zenith 35 – RINEX 2 Raw Data Logging Support. GeoMax Zenith 40 – Added Terrastar Support. DWG File Support – Support for importing 2018. Tangent to Circle Intersection – Added a New Tangent to Circle calculation toolĢ018.